Mod. 529 ETO

Mod. 529/ETO, hot FID Ethylene (Propylene) automatic analyzer.

Special versions of the base Mod. 529 allow to meet the specific requirements of monitoring and control.
The specific analysis of the chemical components increase the efficiency of industrial plant and avoids undesired pollution conditions.

Mod. 529/ETO, Ethylene Oxide automatic analyzer.
Proprietary FID, carbon atoms counter.
Gas chromatographic separation of Ethylene Oxide (Propylene) Fraction from the Total Hydrocarbons.

For stack and environment continuous monitoring.
It specifically measures the Ethylene (Propylene) concentration.

×

Overview

  • Property micro hot FID atom counter.
  • Gas chromatographic separation of Ethylene (Propylene) Fraction from the Total Hydrocarbons.
  • Analytical cycle, 300 sec
  • Benzene LDL, 0.05 ppm
  • Continuous Benzene output and display
  • Real time chromatogram on display
  • Data storage on flash memory
  • Built in auto ignition
  • Local and remote communication through RS 232
  • Easy to integrate in stack systems
  • Rack mounted
 

  Download PDF – Mod. 529 special config.